KrautKramer

Ultrasonic Thickness Gauges - DM5E

The DM5E series wall thickness gages enables you to accomplish a large number of demanding tasks, especially with remaining wall thickness measurements on components subjected to corrosion and erosion.

The DM5E Series wall thickess gages are smart, simple-to-use ultrasonic thickness gages that offer big ultrasonic performance in a small lightweight package. Compact size and ergonomic shape provide comfortable one-hand use.

Instrument:

 
Operating Principle  Ultrasonic pulse-echo method
 Measurement Modes  Depends on Probe and Material, 0.60 mm to 508 mm (0.025” to 20.00”) in IP to 1st BW Measurement Mode, 2.00 mm to 127.0 mm
(0.079” to 5.00”) in Dual-Multi Measurement Mode, the Coating Thickness Range Shall be 0.3 mm to 2.50 mm (0” to 0.098”).
 Measuring Resolution  0.01 mm Default - Selectable 0.01, 0.1 mm (0.001” Default - Selectable 0.001, 0.01”)
 Material Velocity Range  0.508 to 18.699 mm/msec (0.0200 to 0.7362”/msec)
 Material Velocity Resolution  1 m/s (0.0001”/msec)
 Units  Inch or Millimeter
 Calibration  One-Point Cal, On-Block and Off-Block, Two-Point Cal
 Pulser  Excitation Pulse: Spike Pulser
Voltage: 120 V into 50 ohm Load, Using 20 MHz Oscilloscope
 Receiver  Bandwidth 500KHz to 12 MHz @ -3 dB
Gain Automatic Gain Control
 Display Type  High-Resolution Graphical LCD, 64 x 128 Pixels, 53.0 mm x 27.0 mm with Backlight and Adjustable Contrast
 Update Rate  4 Hz or 8 Hz, User Selectable, 24 Hz Scan Mode Capture Rate
 Thickness Value Display  NORMAL View Mode 5 Digit, 10.6 mm (0.4”) High
B-SCAN View Mode 5 Digit, 2.55 mm (0.1”) High
 Display of Last Reading  Solid Filled or Hollow Digits Indicate Coupled or Uncoupled Condition
 Setups  9 Standard Setups for Probes
 Alarm Settings  Minimum and Maximum Alarms, Range of 0.25 mm to 508 mm, 0. (0.010” to 20.00”)
Reading Alternates Between Solid and Hollow When Alarms Are Enabled and Violated
 Power Requirements  2 “AA” Size Batteries
 Battery Life/Operating
Time
 Approximately 60 Hours
 Instrument Shut-0ff  Selectable ALWAYS ON or AUTO OFF After 5, 10, 15, 30 Minutes of Inactivity
 Language  Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese
 I/O Connectors  Transducer Dual Lemo 00 (coax)
Mini-USB Mini-USB to PC
 Temperature Operating -10°C to +50°C (+10°F to +120°F)
Storage -20°C to +60°C (-10°F to +140°F)
 Weight  223 g (0.597 lb) Including Batteries
 Size  138 mm x 32 mm x 75 mm
 Shock  IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g 11ms Impulse Half Sinusoidal Wave Applied 6 Times per Axis
 Sealing  IEC529 / IP54, Dust Proof/Dripping Water Proof as per IEC 529 Specifications for IP54 Classification
 

Data Record Option Features:

 
 Capacity  50,000 Readings
 File Structures  Grid File
 Number of Rows  1 to 50,000
 Number of Columns  1 to 223
 File Naming  Up to 24 Character Alphanumeric Name
 Optional Software  UltraMATE and UltraMATE Lite
 

Probe/Transducers:

 
 DM5E Series Probe / Transducer Specifications 